COMMERCIAL PARKING INVESTMENT SOLUTION

Turn Idle Parking Bays Into Metered Revenue.

Most commercial parking EV charging investments fail for three reasons: buying costly DC hardware for long-stay bays, triggering transformer upgrades, or getting locked into proprietary software that shuts down. MAXGREEN supplies factory-direct 7 kW to 240 kW AC and DC chargers built on open OCPP 1.6J / 2.0.1, dynamic load balancing and built-in energy metering.

Commercial parking EV charging bays with networked wallboxes

Sized around dwell time. Protected against platform lock-in.

3.5–240 kW

Full AC & DC range from our ISO 9001 factory

OCPP 1.6J / 2.0.1

Open protocol—change software without replacing hardware

±1% Meter

Built-in energy metering on MG-Cube & MG-L02

−40% Standby

ENERGY STAR certified on NA MG-L01 & MG-A09

RISK MITIGATION FIRST

Six questions every parking investor asks. Six hardware-level answers.

Before ordering hardware, see how MAXGREEN chargers protect your site against low utilization, unpaid power, software lock-in, transformer limits, bay poaching and maintenance call-outs.

01 · Utilization Risk

“What if drivers rarely plug in?”

The trap: Public chargers typically need ~15% time in use to break even and 30%+ for strong returns. Installing expensive high-power DC on long-stay bays destroys ROI.

Our hardware answer: Match power to dwell time. Where cars park 6–12 hours, install 7–22 kW AC wallboxes at a fraction of DC cost, or use the MG-L02 dual-port pedestal (22+22 kW) so one trenching point serves two bays. Start with 5%–10% of spaces and expand when session logs pass 30% utilization.

02 · Revenue & Billing Leaks

“How do I bill drivers without losing money?”

The trap: Free charging becomes an unpaid electricity bill, while flat $50/month apartment fees lose money when high-mileage drivers consume $200 of power.

Our hardware answer: Every session is metered and logged. MG-Cube and MG-L02 include a built-in ±1% energy meter. Connect to an OCPP billing platform to charge automatically per kWh, per hour or with idle fees—or use ChargeMAX usage logs on private sites to see each user’s exact kWh and collect fees manually on rent or invoices.

03 · Software Shutdown Risk

“What if the software company shuts down?”

The trap: When a closed charging network exits the market, thousands of proprietary commercial chargers can lose billing and remote control overnight.

Our hardware answer: Zero software lock-in. Networked MAXGREEN chargers speak open OCPP 1.6J (JSON over WebSocket) out of the box, and MG-L01 and MG-A09 support over-the-air upgrades to OCPP 2.0.1. Switch platforms anytime by changing the server URL—never the charger.

04 · Transformer & Peak Demand

“Will 20 chargers overload my building supply?”

The trap: Twenty unmanaged 11 kW chargers starting at 18:00 add a 220 kW spike on top of building HVAC and lighting, forcing costly utility transformer upgrades.

Our hardware answer: Dynamic load balancing + off-peak schedules. MG-L02 features CT-based dynamic load balancing and MG-Cube supports DLB current sharing, automatically throttling chargers when building load peaks and restoring full power during cheap overnight tariff hours.

05 · Unauthorized Bay Poaching

“How do I stop outsiders from taking free power?”

The trap: Open parking bays quickly attract neighbouring ride-hail or non-customer vehicles, leaving paying tenants, guests and staff with nowhere to charge.

Our hardware answer: Three-layer access control. Issue MIFARE / ISO 14443A/B NFC cards per resident, room or fleet vehicle; share access codes in the ChargeMAX app; or use ISO 15118 Plug & Charge (supported on MG-L02 and optional on MG-A09).

06 · Field Faults & Downtime

“What happens when a charger faults on a weekend?”

The trap: Field studies of public chargers found real-world uptime averaging 73.7% vs. 84.6% self-reported. Sending an electrician for every minor reset eats your margin.

Our hardware answer: Industrial enclosures + remote recovery. MG-A09, MG-A10, MG-A11 and MG-A13 carry IK10 impact ratings; MG-L01 and MG-A09 are rated IP65 and −30 °C to +50 °C. View faults remotely, trigger remote restarts, push OTA firmware updates, backed by our 30+ factory engineers.

SIZED BY DWELL TIME

Four ready-to-deploy commercial parking packages.

Pick the parking profile that matches how long vehicles stay at your property.

Apartment and office building commercial parking EV charging garage

8–12 Hours Dwell Time · Overnight & Workday

Package A · Apartments, Condos & Office Parks

100% AC Level 2 with dynamic load balancing. Cars sit parked all day or all night, so 7–11 kW (EU) or 40–48 A (NA) refills 60–100 kWh at the lowest cost per bay.

• Recommended hardware: MG-L01 (7–22 kW EU / 40–80 A NA, cETLus & ENERGY STAR), MG-Cube (7–22 kW, ±1% meter & DLB), or MG-L02 (22+22 kW dual-port pedestal with CT load balancing).
• Starter 50-bay layout: 4× MG-L01 or 2× MG-L02 (4 active bays, 28–44 kW shared supply).

Explore MG-L01 Smart Wallbox →

Hotel guest parking lot with commercial EV charging stations

6–10 Hours Dwell Time · Hospitality & Destination

Package B · Hotels, Resorts & Executive Frontages

Architectural or heavy-duty AC wallboxes with RFID room-card or OCPP billing. Appears in hotel booking filters and turns overnight guest stays into high-margin kWh sales.

• Recommended hardware: MG-A08 (87 mm slim black/grey textured housing, 7–22 kW EU / 40–48 A NA) for building façades, or MG-A09 (32–80 A NA, IP65 & IK10, 5"/7" screen, ISO 15118 option, cETLus & ENERGY STAR).
• Starter 40-bay layout: 4–6 AC wallboxes at guest bays + 1 optional 20–30 kW DC unit for daytime visitors.

Compare Smart AC Wallboxes →

Retail shopping centre parking bays for AC and DC fast charging

1–2 Hours Dwell Time · Retail, Dining & Gyms

Package C · Shopping Centres, Supermarkets & Gyms

20–40 kW mid-power DC paired with 22+22 kW dual-port AC. Delivers 25–40 kWh (150–240 km of range) while shoppers dine or browse—without the transformer cost of a 150 kW station.

• Recommended hardware: MG-A10 (20 / 30 / 40 kW DC, >94% efficiency, PF >0.99, CCS2/CHAdeMO/GB/T, 7" touch screen) or MG-A11 (20 / 30 kW compact DC for underground garages) + MG-L02 (22+22 kW AC pedestal).
• Starter retail layout: 2× MG-A10 30 kW DC + 2× MG-L02 dual-port AC (serves 6 bays simultaneously).

View Commercial AC & DC Range →

Commercial DC fast charging hub for high-turnover parking and fleets

20–45 Mins Turnaround · Public Hubs & Fleet Yards

Package D · Commercial Fast-Charge Hubs & Fleet Depots

60–240 kW dual-gun dynamic power-sharing DC for fast public turnarounds, or mixed with overnight AC wallboxes for commercial delivery fleets.

• Recommended hardware: MG-A13 (60 / 80 / 120 / 160 / 200 / 240 kW DC, dual-gun power sharing up to 250 A, ±0.5% voltage precision, >94% efficiency, APFC >0.99, IP54/IK10).
• Starter hub layout: 2–4× MG-A13 120–240 kW dual-gun DC cabinets + optional overnight AC bays.

Read Our Fleet Depot Sizing Guide →

REVENUE & GRID MATHS

Two levers decide your payback: how you price the kWh, and how you cap peak power.

Charging works like any retail energy margin—as long as evening power spikes do not trigger utility demand penalties or transformer upgrades.

1. Automated OCPP Billing + Idle Fees

Connect networked chargers to an OCPP billing platform to buy power at your commercial tariff (e.g. $0.12–$0.18/kWh) and bill drivers automatically per kWh ($0.35–$0.55/kWh), plus per-minute idle fees after charging ends.

2. Usage Logs + Manual Settlement (Zero Fee)

At apartments, condos and private offices, use the ChargeMAX app or RFID cards to log exact kWh per resident or employee, then settle the electricity cost manually on monthly rent, HOA dues or invoices with 0% payment gateway fees.

3. Property Yield & Green Building Credits

Hotels bundle overnight charging into premium room packages; offices and apartments retain EV-driving tenants and earn sustainability points under LEED, BREEAM and ENERGY STAR for Buildings.

GRID CAPACITY COMPARISON

How dynamic load balancing saves a $20k–$80k transformer upgrade.

Illustrative example: 10 commercial parking bays equipped with 22 kW AC charging (five MG-L02 dual-port pedestals or ten wallboxes), where each vehicle needs 45 kWh overnight.

Metric (10 bays · 22 kW AC / 5× MG-L02)

Unmanaged Chargers

MAXGREEN CT Load Balancing / OCPP

18:00 evening peak draw

220 kW instant spike (risks tripping main breaker)

Capped at 60–80 kW (floats with building spare capacity)

00:00–06:00 overnight valley

Chargers sit idle after finishing early at peak rates

Ramps up to full power on cheap off-peak electricity

Morning result at 07:00

10 of 10 vehicles charged

10 of 10 vehicles charged (same kWh delivered)

Utility transformer upgrade?

Often required (3–12 months + $20k–$80k+ capex)

Usually avoided—runs on existing panel headroom

TRANSPARENT ROI & GRID CALCULATOR

Stress-test your parking investment before you buy a single charger.

Pick a site preset or drag the sliders to check monthly net profit, payback period, 5-year cumulative return, active time utilization (vs. the ~15% industry break-even benchmark) and DLB-managed grid load.

Charging ports6 ports
Active connectors across your bays
Rated power / port11 kW
7–22 kW AC or 20–120 kW DC
Sessions / port / day1.5 / day
1.0–2.0 for overnight/work; 3–8 for retail/DC
Energy / session32 kWh
~32 kWh ≈ 180 km of EV driving
Driver tariff ($/kWh)$0.42
Price billed to drivers per kWh
Site power cost ($/kWh)$0.14
Your grid tariff (lower with off-peak schedules)
Hardware + install / port$1,650
Lower per port when using MG-L02 dual-port
Platform & payment fee5%
3–8% on OCPP billing; 0% if settled manually from ChargeMAX kWh logs
Monthly Net Profit
$2,195
8,640 kWh delivered / month
Estimated Payback
4.5 mos
Total investment: $9,900
5-Year Net Return
$121,800
Cumulative profit after capex recovery
Active Time Utilization
18.2%
DLB recommended supply: ~36 kW
5-Year Cumulative Net Cash Flow (After Capex) Suggested: MG-L01 / MG-A08 / MG-A09

Illustrative estimate only (assumptions, not a forecast). Excludes local taxes, civil trenching, utility demand charges and regional grants. Send us your site details below for a custom engineering layout and direct factory quote.

ONE HARDWARE PLATFORM · THREE WAYS TO RUN IT

Start simple today. Switch software anytime without replacing chargers.

Whether you log kWh in our free app for manual settlement or run automated driver billing on an OCPP platform, the underlying MAXGREEN hardware stays the same.

ChargeMAX app charging records for several sites with export

PRIVATE SITES · USAGE TRACKING & MANUAL SETTLEMENT

Track who used how much electricity in the free ChargeMAX app—and settle bills manually.

ChargeMAX records kilowatt-hours and estimated electricity cost per user account or RFID card, but does not process driver payments inside the app. It fits private office car parks, apartments and small communities where the property owner collects electricity costs manually (for example on monthly rent, HOA dues or staff invoices).

• Per-user & per-card energy logs: see who charged, when and how many kWh they consumed, and set your local electricity tariff in the app to calculate the exact amount to collect offline.
• Dual Bluetooth + Wi-Fi control: start and stop sessions over Bluetooth in underground garages with zero cellular signal; usage records sync automatically once back online.
• Multi-user sharing, RFID whitelist & DLB: share access via auth codes or QR codes, manage MIFARE RFID cards, schedule off-peak charging and configure dynamic load balancing.

See Full ChargeMAX App Capabilities →

COMMERCIAL HARDWARE SPECIFICATIONS

The hardware behind the numbers.

All models are built on our four ISO 9001 production lines in Foshan. Combine AC wallboxes, dual-port pedestals, compact DC and high-power DC in a single mixed-container shipment.

Model & Best Parking Role

Power / Current & Voltage

Connectors & Protection

Metering, Load Balancing & UI

Protocol & Verified Compliance

MG-L02 Dual-Port AC Pedestal
Shared bays (1 post = 2 bays)

22 + 22 kW (32 A × 2)
3P 200–240 Vac

Type 2 × 2 · IP54 · SECC steel
−25 °C to +50 °C

Built-in ±1% energy meter · CT dynamic load balancing · 7" LCD

OCPP 1.6J · ISO 15118 PnC · NFC · RCD Type B · LAN/Wi-Fi/BT (4G opt.)

MG-L01 Smart AC Wallbox
1:1 overnight & workplace bays

EU: 7 / 11 / 22 kW
NA: 40 / 48 / 80 A (9.6–19.2 kW)

Type 2 / SAE J1772 · IP65 (EU) / Type 4 (NA) · −30 °C to +50 °C

4.3" LCD or LED · Type A RCD + DC 6 mA · Wall or pedestal mount

OCPP 1.6J & 2.0.1 OTA · NFC · NA: cETLus Listed & ENERGY STAR

MG-A09 Commercial Wallbox
Heavy-duty North American bays

32 / 40 / 48 / 80 A
(7.6–19.2 kW, 208/240 Vac)

SAE J1772 · IP65 & IK10
−30 °C to +50 °C

5" or 7" LCD · 8-layer protection + relay weld & CCID self-test

OCPP 1.6J & 2.0.1 OTA · ISO 15118 PnC option · cETLus, ENERGY STAR & FCC

MG-Cube Smart AC Wallbox
Apartments & residential portfolios

7 kW (1P) · 11 / 22 kW (3P)
200–240 / 380–400 Vac

Type 2 · Flame-retardant PC
−25 °C to +50 °C

Built-in ±1% energy meter · App DLB load balancing · 2.4" LCD

OCPP 1.6J · NFC · LAN/Wi-Fi/BT (4G opt.) · Built to IEC 61851-1 / -21-2

MG-A08 Slim AC Wallbox
Hotels & architectural façades

EU: 7 / 11 / 22 kW
NA: 40 / 48 A (208/250 Vac)

Type 2 / SAE J1772 · IP54 / NEMA 3S · 87 mm slim profile

2.8" or 4.3" screen · Black or grey textured finish · Wall/pedestal

OCPP 1.6J · NFC (ISO 14443A/B, MIFARE) · App or OCPP firmware

MG-A11 Compact DC Charger
Underground garages & tight depots

20 / 30 kW DC
150–1000 Vdc

CCS2 · IP54 & IK10
−25 °C to +50 °C

7" touch screen · >94% efficiency · PF >0.99 · IMD + emergency stop

OCPP · LAN · Space-saving cabinet for low-clearance parking structures

MG-A10 / MG-A13 DC Fast
Retail 1–2 h stays & fast hubs

MG-A10: 20 / 30 / 40 kW DC
MG-A13: 60–240 kW DC (up to 250 A)

CCS2 · CHAdeMO · GB/T
IP54 & IK10 · −25 °C to +50 °C

7" touch screen · Dual-gun dynamic power sharing (MG-A13) · >94% eff.

OCPP · 4G / LAN · RFID, QR code & mobile payment · APFC >0.99

European installations require a suitably rated upstream breaker. Certificates and full datasheets for any model are sent within one working day of your request.

DELIVERY & INVESTOR FAQ

From site check to first paid session.

How we take your parking project from initial electrical sizing to live operation.

6-Step Factory Rollout

1. Site & Power Check (Day 1): Share bay count, stay duration and spare kVA; we return a recommended AC/DC mix.

2. OCPP Sandbox Test: Test message flows with your software platform before volume production.

3. Stock or OEM Build: Stock models ship in 3 working days; custom OEM branding (from 200 units) ships in 25–30 working days.

4. Mixed-Order Dispatch: Combine AC wallboxes, pedestals, DC chargers and cables in one shipment.

5. Local Install + Remote Support: Installed by your electrician, backed by our 30+ factory engineers.

6. Go Live & Scale: 2-year station warranty (RMA response within 2 working days); add bays as utilization grows.

How many parking spaces should we electrify in Phase 1?

Most commercial properties start by electrifying 5% to 10% of their parking bays while laying conduit for 20% to 50% of spaces (in the EU, Article 14 of Directive 2024/1275 requires at least 1 recharging point per 10 spaces in existing non-residential car parks with more than 20 spaces by 2027). Using the MG-L02 dual-port pedestal lets a single installation point serve two adjacent bays, and session logs show you exactly when utilization passes 30% so you can expand with confidence.

Can the ChargeMAX app collect payments from drivers?

No. ChargeMAX is a free management app that tracks who charged and how many kilowatt-hours they used (by user account or RFID card) and calculates the electricity cost based on your local tariff, so you can settle bills manually (for example on monthly rent, HOA dues or staff invoices). If you need automated driver payments by credit card, QR code or mobile wallet, choose our OCPP network version and connect it to an OCPP billing platform.

Can we run AC wallboxes and DC fast chargers on the same billing platform?

Yes. All networked MAXGREEN AC models (MG-L01, MG-L02, MG-A09, MG-Cube, MG-A08) and DC models (MG-A10, MG-A11, MG-A13) communicate over standard OCPP 1.6J (with OTA upgrade to OCPP 2.0.1 on MG-L01 and MG-A09). You can manage tariffs, RFID cards and energy reports for both AC and DC bays inside one OCPP back end.

What if our underground parking garage has weak or no cellular signal?

Every networked MAXGREEN wallbox includes wired Ethernet (RJ45 LAN), Wi-Fi and Bluetooth as standard, with optional 4G SIM connectivity. In underground garages, you can connect chargers over local LAN or Wi-Fi, authorize drivers via local MIFARE RFID whitelists, or use the ChargeMAX app version which starts and stops sessions offline over Bluetooth.

What is the minimum order quantity (MOQ) for a commercial parking project?

For standard MAXGREEN models, there is no rigid high MOQ—property owners, installers and distributors can place smaller project orders or mix AC wallboxes, dual-port pedestals and DC fast chargers in one shipment. Custom OEM branding with your logo and packaging starts at 200 units.

How do you support our local electrical contractor during and after installation?

Every shipment includes English (or localized) installation manuals and wiring diagrams. Our 30+ person technical team provides remote commissioning support, OCPP platform sandbox testing, over-the-air firmware updates and a 2-year warranty on charging stations (1 year on portables and adapters) with RMA responses within 2 working days.

FREE SITE SIZING & FACTORY QUOTE

Tell us about your parking bays. We’ll run the numbers with you.

Share your country, parking space count and available power. Our engineering and sales team will reply with a recommended AC/DC layout, datasheets and direct factory pricing.

Your Custom Parking Proposal Includes:

What to include in your message:

• Site type & bay count: e.g. 60-bay apartment garage, 40-bay hotel or 25-bay retail car park.

• Available electrical supply: single- or three-phase voltage and spare kVA / amperage.

• Target market & connectors: Europe (Type 2 / CCS2), North America (SAE J1772 / NACS) or GB/T.

• How you plan to run them: ChargeMAX app (usage logs + manual settlement), turnkey management platform, your own OCPP billing back end, or OEM white-label.

Direct factory contact: [email protected] · WhatsApp / Tel: +86 186 1300 8055

Get a quote and solutions

Get a quote and solutions

Foshan Maxgreen New Energy Technology Ltd.

How should we address you?
If you have a company
We will reply to your inquiry as soon as possible.
Cookie preferences
We value your privacy

We use cookies to keep this website secure and working properly, to remember your choices and, with your permission, to understand how the site is used and to measure our marketing. You can accept all, reject all non-essential cookies, or choose by category. Privacy Policy Cookie Policy